Brand
|
Model
|
PN
|
Port to port length
|
Phase/ Voltage
|
Connection
|
Replacement XL
|
Replacement XLplus
|
Port to port length
|
Phase/ Voltage
|
Comment
|
|
Lowara
|
AFLC 30-120
|
6/10
|
180
|
1~230 V
|
G 2″
|
|
|
|
|
Sorry, no direct replacement is available
|
|
Lowara
|
AFLC 30-120 modbus
|
6/10
|
180
|
1~230 V
|
G 2″
|
|
|
|
|
Sorry, no direct replacement is available
|
|
Lowara
|
ETC 32-11
|
6/10
|
180
|
1~230 V
|
G 2″
|
ecocirc XL 32-120
|
ecocirc XLplus 32-120
|
220
|
1~230 V
|
The replacement pump has slightly lower capacity
|
|
Lowara
|
TC 32-10
|
6/10
|
180
|
1~230 V
|
G 2″
|
ecocirc XL 32-120
|
ecocirc XLplus 32-120
|
220
|
1~230 V
|
|
|
Lowara
|
TC 32-10T
|
6/10
|
180
|
3~400 V
|
G 2″
|
ecocirc XL 32-120
|
ecocirc XLplus 32-120
|
220
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
TC 32-4
|
6/10
|
180
|
1~230 V
|
G 2″
|
ecocirc XL 32-80
|
ecocirc XLplus 32-80
|
220
|
1~230 V
|
|
|
Lowara
|
TC 32-5
|
6/10
|
180
|
1~230 V
|
G 2″
|
ecocirc XL 32-60
|
ecocirc XLplus 32-60
|
220
|
1~230 V
|
|
|
Lowara
|
TC 32-8
|
6/10
|
180
|
1~230 V
|
G 2″
|
ecocirc XL 32-80
|
ecocirc XLplus 32-80
|
220
|
1~230 V
|
|
|
Lowara
|
TCG 32-4
|
6/10
|
180
|
1~230 V
|
G 2″
|
|
|
|
|
Sorry, no direct replacement is available
|
|
Lowara
|
TCG 32-5
|
6/10
|
180
|
1~230 V
|
G 2″
|
|
|
|
|
Sorry, no direct replacement is available
|
|
Lowara
|
TCG 32-8
|
6/10
|
180
|
1~230 V
|
G 2″
|
|
|
|
|
Sorry, no direct replacement is available
|
|
Lowara
|
AFLC 32-120
|
6/10
|
220
|
1~230 V
|
DN 32
|
ecocirc XL 32-120 F
|
ecocirc XLplus 32-120 F
|
220
|
1~230 V
|
|
|
Lowara
|
AFLC 32-120 modbus
|
6/10
|
220
|
1~230 V
|
DN 32
|
|
ecocirc XLplus 32-120 F
|
220
|
1~230 V
|
|
|
Lowara
|
AFLCG 32-120
|
6/10
|
220
|
1~230 V
|
DN 32
|
ecocirc XL D 32-120 F
|
ecocirc XLplus D 32-120 F
|
220
|
1~230 V
|
|
|
Lowara
|
AFLCG 32-120 modbus
|
6/10
|
220
|
1~230 V
|
DN 32
|
|
ecocirc XLplus D 32-120 F
|
220
|
1~230 V
|
|
|
Lowara
|
AFLC 40-120
|
6/10
|
250
|
1~230 V
|
DN 40
|
ecocirc XL 40-120 F
|
ecocirc XLplus 40-120 F
|
250
|
1~230 V
|
|
|
Lowara
|
AFLC 40-120 modbus
|
6/10
|
250
|
1~230 V
|
DN 40
|
|
ecocirc XLplus 40-120 F
|
250
|
1~230 V
|
|
|
Lowara
|
AFLCG 40-120
|
6/10
|
250
|
1~230 V
|
DN 40
|
ecocirc XL D 40-120 F
|
ecocirc XLplus D 40-120 F
|
250
|
1~230 V
|
|
|
Lowara
|
AFLCG 40-120 modbus
|
6/10
|
250
|
1~230 V
|
DN 40
|
|
ecocirc XLplus D 40-120 F
|
250
|
1~230 V
|
|
|
Lowara
|
EFC 40-10
|
6/10
|
250
|
1~230 V
|
DN 40
|
ecocirc XL 40-120 F
|
ecocirc XLplus 40-120 F
|
250
|
1~230 V
|
|
|
Lowara
|
EFCG 40-10
|
6/10
|
250
|
1~230 V
|
DN 40
|
ecocirc XL D 40-120 F
|
ecocirc XLplus D 40-120 F
|
250
|
1~230 V
|
|
|
Lowara
|
EFLC 40-11
|
6/10
|
250
|
1~230 V
|
DN 40
|
ecocirc XL 40-120 F
|
ecocirc XLplus 40-120 F
|
250
|
1~230 V
|
|
|
Lowara
|
EFLC 40-9
|
6/10
|
250
|
1~230 V
|
DN 40
|
ecocirc XL 40-100 F
|
ecocirc XLplus 40-100 F
|
220
|
1~230 V
|
The replacement pump has a shorter port-to-port length
|
|
Lowara
|
EFLCG 40-11
|
6/10
|
250
|
1~230 V
|
DN 40
|
ecocirc XL D 40-120 F
|
ecocirc XLplus D 40-120 F
|
250
|
1~230 V
|
|
|
Lowara
|
EFLCG 40-9
|
6/10
|
250
|
1~230 V
|
DN 40
|
ecocirc XL D 40-100 F
|
ecocirc XLplus D 40-100 F
|
220
|
1~230 V
|
The replacement pump has a shorter port-to-port length
|
|
Lowara
|
FC 40-10
|
6/10
|
250
|
1~230 V
|
DN 40
|
ecocirc XL 40-120 F
|
ecocirc XLplus 40-120 F
|
250
|
1~230 V
|
|
|
Lowara
|
FC 40-10T
|
6/10
|
250
|
3~400 V
|
DN 40
|
ecocirc XL 40-120 F
|
ecocirc XLplus 40-120 F
|
250
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FC 40-7
|
6/10
|
250
|
1~230 V
|
DN 40
|
ecocirc XL 40-120 F
|
ecocirc XLplus 40-120 F
|
250
|
1~230 V
|
|
|
Lowara
|
FC 40-7T
|
6/10
|
250
|
3~400 V
|
DN 40
|
ecocirc XL 40-120 F
|
ecocirc XLplus 40-120 F
|
250
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FCG 40-10
|
6/10
|
250
|
1~230 V
|
DN 40
|
ecocirc XL D 40-120 F
|
ecocirc XLplus D 40-120 F
|
250
|
1~230 V
|
|
|
Lowara
|
FCG 40-10T
|
6/10
|
250
|
3~400 V
|
DN 40
|
ecocirc XL D 40-120 F
|
ecocirc XLplus D 40-120 F
|
250
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FCG 40-7
|
6/10
|
250
|
1~230 V
|
DN 40
|
ecocirc XL D 40-120 F
|
ecocirc XLplus D 40-120 F
|
250
|
1~230 V
|
|
|
Lowara
|
FCG 40-7T
|
6/10
|
250
|
3~400 V
|
DN 40
|
ecocirc XL D 40-120 F
|
ecocirc XLplus D 40-120 F
|
250
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FLC 40-10
|
6/10
|
250
|
1~230 V
|
DN 40
|
ecocirc XL 40-120 F
|
ecocirc XLplus 40-120 F
|
250
|
1~230 V
|
|
|
Lowara
|
FLC 40-10T
|
6/10
|
250
|
3~400 V
|
DN 40
|
ecocirc XL 40-120 F
|
ecocirc XLplus 40-120 F
|
250
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FLC 40-5
|
6/10
|
250
|
1~230 V
|
DN 40
|
ecocirc XL 40-80 F
|
ecocirc XLplus 40-80 F
|
220
|
1~230 V
|
|
|
Lowara
|
FLC 40-5T
|
6/10
|
250
|
3~400 V
|
DN 40
|
ecocirc XL 40-80 F
|
ecocirc XLplus 40-80 F
|
220
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FLC 40-7
|
6/10
|
250
|
1~230 V
|
DN 40
|
ecocirc XL 40-100 F
|
ecocirc XLplus 40-100 F
|
220
|
1~230 V
|
|
|
Lowara
|
FLC 40-7T
|
6/10
|
250
|
3~400 V
|
DN 40
|
ecocirc XL 40-100 F
|
ecocirc XLplus 40-100 F
|
220
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FLCG 40-10
|
6/10
|
250
|
1~230 V
|
DN 40
|
ecocirc XL D 40-120 F
|
ecocirc XLplus D 40-120 F
|
250
|
1~230 V
|
|
|
Lowara
|
FLCG 40-10T
|
6/10
|
250
|
3~400 V
|
DN 40
|
ecocirc XL D 40-120 F
|
ecocirc XLplus D 40-120 F
|
250
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FLCG 40-5
|
6/10
|
250
|
1~230 V
|
DN 40
|
ecocirc XL D 40-80 F
|
ecocirc XLplus D 40-80 F
|
220
|
1~230 V
|
The replacement pump has a shoreter port-to-port length
|
|
Lowara
|
FLCG 40-5T
|
6/10
|
250
|
3~400 V
|
DN 40
|
ecocirc XL D 40-80 F
|
ecocirc XLplus D 40-80 F
|
220
|
1~230 V
|
The replacement pump has a shorter port-to-port length and is 1~
|
Lowara
|
FLCG 40-7
|
6/10
|
250
|
1~230 V
|
DN 40
|
ecocirc XL D 40-100 F
|
ecocirc XLplus D 40-100 F
|
220
|
1~230 V
|
The replacement pump has a shoreter port-to-port length
|
|
Lowara
|
FLCG 40-7T
|
6/10
|
250
|
3~400 V
|
DN 40
|
ecocirc XL D 40-100 F
|
ecocirc XLplus D 40-100 F
|
220
|
1~230 V
|
The replacement pump has a shorter port-to-port length and is 1~
|
Lowara
|
AFLC 50-140
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL 50-120 F
|
ecocirc XLplus 50-120 F
|
280
|
1~230 V
|
|
|
Lowara
|
AFLC 50-140 modbus
|
6/10
|
280
|
1~230 V
|
DN 50
|
|
ecocirc XLplus 50-120 F
|
280
|
1~230 V
|
|
|
Lowara
|
AFLC 50-90
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL 50-80 F
|
ecocirc XLplus 50-80 F
|
280
|
1~230 V
|
|
|
Lowara
|
AFLC 50-90 modbus
|
6/10
|
280
|
1~230 V
|
DN 50
|
|
ecocirc XLplus 50-80 F
|
280
|
1~230 V
|
|
|
Lowara
|
AFLCG 50-140
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL D 50-120 F
|
ecocirc XLplus D 50-120 F
|
280
|
1~230 V
|
|
|
Lowara
|
AFLCG 50-140 modbus
|
6/10
|
280
|
1~230 V
|
DN 50
|
|
ecocirc XLplus D 50-120 F
|
280
|
1~230 V
|
|
|
Lowara
|
EFC 50-10
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL 50-120 F
|
ecocirc XLplus 50-120 F
|
280
|
1~230 V
|
|
|
Lowara
|
EFCG 50-10
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL D 50-120 F
|
ecocirc XLplus D 50-120 F
|
280
|
1~230 V
|
|
|
Lowara
|
EFLC 50-12
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL 50-120 F
|
ecocirc XLplus 50-120 F
|
280
|
1~230 V
|
|
|
Lowara
|
EFLCG 50-12
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL D 50-120 F
|
ecocirc XLplus D 50-120 F
|
280
|
1~230 V
|
|
|
Lowara
|
FC 50-11
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL 50-120 F
|
ecocirc XLplus 50-120 F
|
280
|
1~230 V
|
|
|
Lowara
|
FC 50-11T
|
6/10
|
280
|
3~400 V
|
DN 50
|
ecocirc XL 50-120 F
|
ecocirc XLplus 50-120 F
|
280
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FC 50-4
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL 50-80 F
|
ecocirc XLplus 50-80 F
|
280
|
1~230 V
|
|
|
Lowara
|
FC 50-4T
|
6/10
|
280
|
3~400 V
|
DN 50
|
ecocirc XL 50-80 F
|
ecocirc XLplus 50-80 F
|
280
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FC 50-8
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL 50-80 F
|
ecocirc XLplus 50-80 F
|
280
|
1~230 V
|
|
|
Lowara
|
FC 50-8T
|
6/10
|
280
|
3~400 V
|
DN 50
|
ecocirc XL 50-80 F
|
ecocirc XLplus 50-80 F
|
280
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FCG 50-11
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL D 50-120 F
|
ecocirc XLplus D 50-120 F
|
280
|
1~230 V
|
|
|
Lowara
|
FCG 50-11T
|
6/10
|
280
|
3~400 V
|
DN 50
|
ecocirc XL D 50-120 F
|
ecocirc XLplus D 50-120 F
|
280
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FCG 50-4
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL D 50-80 F
|
ecocirc XLplus D 50-80 F
|
280
|
1~230 V
|
|
|
Lowara
|
FCG 50-4T
|
6/10
|
280
|
3~400 V
|
DN 50
|
ecocirc XL D 50-80 F
|
ecocirc XLplus D 50-80 F
|
280
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FCG 50-8
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL D 50-80 F
|
ecocirc XLplus D 50-80 F
|
280
|
1~230 V
|
|
|
Lowara
|
FCG 50-8T
|
6/10
|
280
|
3~400 V
|
DN 50
|
ecocirc XL D 50-80 F
|
ecocirc XLplus D 50-80 F
|
280
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FLC 50-10
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL 50-80 F
|
ecocirc XLplus 50-80 F
|
280
|
1~230 V
|
|
|
Lowara
|
FLC 50-10T
|
6/10
|
280
|
3~400 V
|
DN 50
|
ecocirc XL 50-80 F
|
ecocirc XLplus 50-80 F
|
280
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FLC 50-13
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL 50-120 F
|
ecocirc XLplus 50-120 F
|
280
|
1~230 V
|
|
|
Lowara
|
FLC 50-13T
|
6/10
|
280
|
3~400 V
|
DN 50
|
ecocirc XL 50-120 F
|
ecocirc XLplus 50-120 F
|
280
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FLC 50-18T
|
6/10
|
280
|
3~400 V
|
DN 50
|
|
|
|
|
Sorry, no direct replacement is available
|
|
Lowara
|
FLC 50-5
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL 50-80 F
|
ecocirc XLplus 50-80 F
|
280
|
1~230 V
|
|
|
Lowara
|
FLC 50-5T
|
6/10
|
280
|
3~400 V
|
DN 50
|
ecocirc XL 50-80 F
|
ecocirc XLplus 50-80 F
|
280
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FLC 50-8
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL 50-80 F
|
ecocirc XLplus 50-80 F
|
280
|
1~230 V
|
|
|
Lowara
|
FLC 50-8T
|
6/10
|
280
|
3~400 V
|
DN 50
|
ecocirc XL 50-80 F
|
ecocirc XLplus 50-80 F
|
280
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FLCG 50-10
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL D 50-80 F
|
ecocirc XLplus D 50-80 F
|
280
|
1~230 V
|
|
|
Lowara
|
FLCG 50-10T
|
6/10
|
280
|
3~400 V
|
DN 50
|
ecocirc XL D 50-80 F
|
ecocirc XLplus D 50-80 F
|
280
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FLCG 50-5
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL D 50-80 F
|
ecocirc XLplus D 50-80 F
|
280
|
1~230 V
|
|
|
Lowara
|
FLCG 50-5T
|
6/10
|
280
|
3~400 V
|
DN 50
|
ecocirc XL D 50-80 F
|
ecocirc XLplus D 50-80 F
|
280
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FLCG 50-8
|
6/10
|
280
|
1~230 V
|
DN 50
|
ecocirc XL D 50-80 F
|
ecocirc XLplus D 50-80 F
|
280
|
1~230 V
|
|
|
Lowara
|
FLCG 50-8T
|
6/10
|
280
|
3~400 V
|
DN 50
|
ecocirc XL D 50-80 F
|
ecocirc XLplus D 50-80 F
|
280
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
AFLC 65-90
|
6/10
|
340
|
1~230 V
|
DN 65
|
ecocirc XL 65-120 F
|
ecocirc XLplus 65-120 F
|
340
|
1~230 V
|
|
|
Lowara
|
AFLC 65-90 modbus
|
6/10
|
340
|
1~230 V
|
DN 65
|
|
ecocirc XLplus 65-120 F
|
340
|
1~230 V
|
|
|
Lowara
|
EFC 65-8
|
6/10
|
340
|
1~230 V
|
DN 65
|
ecocirc XL 65-80 F
|
ecocirc XLplus 65-80 F
|
340
|
1~230 V
|
|
|
Lowara
|
EFCG 65-8
|
6/10
|
340
|
1~230 V
|
DN 65
|
ecocirc XL D 65-80 F
|
ecocirc XLplus D 65-80 F
|
340
|
1~230 V
|
|
|
Lowara
|
EFLC 65-12
|
6/10
|
340
|
1~230 V
|
DN 65
|
ecocirc XL 65-120 F
|
ecocirc XLplus 65-120 F
|
340
|
1~230 V
|
|
|
Lowara
|
EFLCG 65-12
|
6/10
|
340
|
1~230 V
|
DN 65
|
ecocirc XL D 65-120 F
|
ecocirc XLplus D 65-120 F
|
340
|
1~230 V
|
|
|
Lowara
|
FC 65-10
|
6/10
|
340
|
1~230 V
|
DN 65
|
ecocirc XL 65-120 F
|
ecocirc XLplus 65-120 F
|
340
|
1~230 V
|
|
|
Lowara
|
FC 65-10T
|
6/10
|
340
|
3~400 V
|
DN 65
|
ecocirc XL 65-120 F
|
ecocirc XLplus 65-120 F
|
340
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FC 65-14T
|
6/10
|
340
|
3~400 V
|
DN 65
|
|
|
|
|
Sorry, no direct replacement is available
|
|
Lowara
|
FC 65-7
|
6/10
|
340
|
1~230 V
|
DN 65
|
ecocirc XL 65-80 F
|
ecocirc XLplus 65-80 F
|
340
|
1~230 V
|
|
|
Lowara
|
FC 65-7T
|
6/10
|
340
|
3~400 V
|
DN 65
|
ecocirc XL 65-80 F
|
ecocirc XLplus 65-80 F
|
340
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FCG 65-10
|
6/10
|
340
|
1~230 V
|
DN 65
|
ecocirc XL D 65-120 F
|
ecocirc XLplus D 65-120 F
|
340
|
1~230 V
|
|
|
Lowara
|
FCG 65-10T
|
6/10
|
340
|
3~400 V
|
DN 65
|
ecocirc XL D 65-120 F
|
ecocirc XLplus D 65-120 F
|
340
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FCG 65-14T
|
6/10
|
340
|
3~400 V
|
DN 65
|
|
|
|
|
Sorry, no direct replacement is available
|
|
Lowara
|
FCG 65-7
|
6/10
|
340
|
1~230 V
|
DN 65
|
ecocirc XL D 65-80 F
|
ecocirc XLplus D 65-80 F
|
340
|
1~230 V
|
|
|
Lowara
|
FCG 65-7T
|
6/10
|
340
|
3~400 V
|
DN 65
|
ecocirc XL D 65-80 F
|
ecocirc XLplus D 65-80 F
|
340
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FLC 65-10
|
6/10
|
340
|
1~230 V
|
DN 65
|
ecocirc XL 65-120 F
|
ecocirc XLplus 65-120 F
|
340
|
1~230 V
|
|
|
Lowara
|
FLC 65-10T
|
6/10
|
340
|
3~400 V
|
DN 65
|
ecocirc XL 65-120 F
|
ecocirc XLplus 65-120 F
|
340
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FLC 65-12
|
6/10
|
340
|
1~230 V
|
DN 65
|
ecocirc XL 65-120 F
|
ecocirc XLplus 65-120 F
|
340
|
1~230 V
|
|
|
Lowara
|
FLC 65-12T
|
6/10
|
340
|
3~400 V
|
DN 65
|
ecocirc XL 65-120 F
|
ecocirc XLplus 65-120 F
|
340
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FLC 65-16T
|
6/10
|
340
|
3~400 V
|
DN 65
|
|
|
|
|
Sorry, no direct replacement is available
|
|
Lowara
|
FLC 65-7
|
6/10
|
340
|
1~230 V
|
DN 65
|
ecocirc XL 65-80 F
|
ecocirc XLplus 65-80 F
|
340
|
1~230 V
|
|
|
Lowara
|
FLC 65-7T
|
6/10
|
340
|
3~400 V
|
DN 65
|
ecocirc XL 65-80 F
|
ecocirc XLplus 65-80 F
|
340
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FLCG 65-10
|
6/10
|
340
|
1~230 V
|
DN 65
|
ecocirc XL D 65-120 F
|
ecocirc XLplus D 65-120 F
|
340
|
1~230 V
|
|
|
Lowara
|
FLCG 65-10T
|
6/10
|
340
|
3~400 V
|
DN 65
|
ecocirc XL D 65-120 F
|
ecocirc XLplus D 65-120 F
|
340
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FLCG 65-12
|
6/10
|
340
|
1~230 V
|
DN 65
|
ecocirc XL D 65-120 F
|
ecocirc XLplus D 65-120 F
|
340
|
1~230 V
|
|
|
Lowara
|
FLCG 65-12T
|
6/10
|
340
|
3~400 V
|
DN 65
|
ecocirc XL D 65-120 F
|
ecocirc XLplus D 65-120 F
|
340
|
1~230 V
|
The replacement pump is 1~
|
|
Lowara
|
FLCG 65-16T
|
6/10
|
340
|
3~400 V
|
DN 65
|
|
|
|
|
Sorry, no direct replacement is available
|
|
Lowara
|
FLCG 65-7
|
6/10
|
340
|
1~230 V
|
DN 65
|
ecocirc XL D 65-80 F
|
ecocirc XLplus D 65-80 F
|
340
|
1~230 V
|
|
|
Lowara
|
FLCG 65-7T
|
6/10
|
340
|
3~400 V
|
DN 65
|
ecocirc XL D 65-80 F
|
ecocirc XLplus D 65-80 F
|
340
|
1~230 V
|
The replacement pump is 1~
|
|